Parts and Instruction Manual
Page 6
Circuit Breakers
A MAIN CONTROL BREAKER
B BRUSH MOTOR BREAKER
C VACUUM MOTOR BREAKER
BCA
The circuit breaker is located at the bottom of
the back panel of the machine.The 4-amp
breaker (A) protects the main controls circuit,
The 30-amp breaker (B) protects the brush
motor circuit, and the 20-amp breaker (C)
protects the vacuum motor circuit.
Battery Compartment
The battery compartment is located under the re-
covery tank. The Battery compartment can be ac-
cessed for servicing and maintenance by tilting the
recovery tank (make sure recovery tank has been
drained before tilting). The battery compartment
contains two 12-volt batteries connected in series.
Connect the batteries according to the battery con-
nection diagram (see diagram). The recommended
batteries are 105Ah (Minuteman P/N 956712) or
100Ah (minuteman P/N 956100) Gel. The battery
tray may be drained if neccessary using the or-
ange drain hose located above the rear caster on
the right side of the machine.
If any of the functions above are not
operating, check if the circuit breaker buttons
have tripped. Press to reset.