After Use
After Use
1. When finished scrubbing, lift the scrub deck and turn the solution lever off. Lift the rear squeegee. Move the machine
to a service area for daily maintenance and review items that may need service.
2. Empty the solution tank by disconnecting the solution tank drain hose from the barb fitting and routing hose to a
drain. Rinse the tank with clean water to prevent any buildup of dried chemicals that could clog the plumbing inside the
recovery tank, and the drain hose cap..
3. Empty and clean the recovery tank by flushing with a hose. Be sure to also clean the float shut off screen.
4. Remove the brushe or pad holder and rinse them in warm water and hang to dry.
5. Remove the rear squeegee, rinse with warm water and reinstall after cleaning.
6. Check the maintenance schedule in the next section and perform any required maintenance before storing the
machine.
7. Store the machine indoors in a clean dry place. Keep from freezing. Leave solution and recovery tank lids open for
ventilation to prevent odor buildup.
8. Turn Key switch OFF (O) and remove key.